DeLonghi display messages — what they mean
DeLonghi has no numeric codes — the machine writes in WORDS. The same applies to AEG, Smeg, Hotpoint-Ariston and Electrolux ECG: inside they are DeLonghi.
- Fill the water tank
- The tank is empty or not pushed fully home.
- Grind too fine
- Either the grind really is too fine and coffee runs too slowly, or there is air in the system after a badly fitted filter.
- Empty the grounds container
- The container is full OR more than three days have passed since the last coffee. Few people know the second one — the machine counts time as well as servings.
- Insert the grounds container
- After washing, the container was not put back.
- Insert the brew unit
- The brew unit is missing or not clicked into place.
- Close the door
- The service door is open.
- Fill the bean container
- The machine is out of beans.
- General alarm
- The inside of the machine is very dirty. If the message stays after a thorough clean, dirt is not the cause and we have to look deeper.
- Descale
- Time to descale.
- Reduce the coffee amount
- Too much ground coffee was added.
- Replace the filter
- The softening filter in the tank is used up.
- Add ground coffee
- Ground-coffee mode was selected but no coffee was added. Or the funnel is clogged.
- Temperature too low
- The machine has not warmed up yet. If the message does not clear, the problem is the heating or the sensor.
If the machine only shows a general alarm with no text, there is nothing to read from it. It is one message for every case and has to be checked in the workshop.
What you can check yourself
- Switch off the DeLonghi, unplug for 30 seconds and switch on again.
- Check that the water tank and drip tray are seated correctly.
- If the brew unit is removable — take it out, rinse with warm water and refit until it clicks.
- Do not reset the machine in a loop when the message returns.
- Bring the machine to KAWA PRO 2 — diagnosis is free.
Important
Don't switch the machine on and off over and over to make the error "go away", and never force the brew unit. If the code comes back after a normal restart, it is a real fault and the machine should be taken to a service centre without delay. Our diagnosis is free.
Tell us what's wrong with your machine — we'll call you back or send an SMS, advise and arrange the drop-off. Diagnosis is free.